Laparoscopically assisted ventriculoperitoneal shunt placement: a prospective randomized controlled trial

Philippe Schucht, Vanessa Banz, Markus Trochsler, Samuel Iff, Anna Krähenbühl, Michael Reinert, Juergen Beck, Andreas Raabe, Daniel Candinas, Dominique Kuhlen, Luigi Mariani

Research output: Contribution to journalArticlepeer-review

Abstract

OBJECT
In ventriculoperitoneal (VP) shunt surgery, laparoscopic assistance can be used for placement of the peritoneal catheter. Until now, the efficacy of laparoscopic shunt placement has been investigated only in retrospective and nonrandomized prospective studies, which have reported decreased distal shunt dysfunction rates in patients undergoing laparascopic placement compared with mini-laparotomy cohorts. In this randomized controlled trial the authors compared rates of shunt failure in patients who underwent laparoscopic surgery for peritoneal catheter placement with rates in patients who underwent traditional mini-laparotomy.

METHODS
One hundred twenty patients scheduled for VP shunt surgery were randomized to laparoscopic surgery or mini-laparotomy for insertion of the peritoneal catheter. The primary endpoint was the rate of overall shunt complication or failure within the first 12 months after surgery. Secondary endpoints were distal shunt failure, overall complication/ failure, duration of surgery and hospitalization, and morbidity.

RESULTS
The overall shunt complication/failure rate was 15% (9 of 60 cases) in the laparoscopic group and 18.3% (11 of 60 cases) in the mini-laparotomy group (p = 0.404). Patients in the laparoscopic group had no distal shunt failures; in contrast, 5 (8%) of 60 patients in the mini-laparotomy group experienced distal shunt failure (p = 0.029). Intraoperative complications occurred in 2 patients (both in the laparoscopic group), and abdominal pain led to catheter removal in 1 patient per group. Infections occurred in 1 patient in the laparoscopic group and 3 in the mini-laparotomy group. The mean durations of surgery and hospitalization were similar in the 2 groups.

CONCLUSIONS
While overall shunt failure rates were similar in the 2 groups, the use of laparoscopic shunt placement significantly reduced the rate of distal shunt failure compared with mini-laparotomy.
Original languageEnglish
Pages (from-to)1058-1067
JournalJournal of Neurosurgery
Volume122
Issue number5
DOIs
Publication statusPublished - 2015

Fingerprint

Dive into the research topics of 'Laparoscopically assisted ventriculoperitoneal shunt placement: a prospective randomized controlled trial'. Together they form a unique fingerprint.

Cite this